+34 620 10 75 37info@nanbiosis.com

Singular

Singular

U16-S07. Evaluation of the adhesion capacities and formation of biolayers of microorganisms on materials. Evaluation of bactericidal and/or bacteriostatic responses of materials. OUTSTANDING

Description:

Evaluation of the adhesion of microorganisms to surfaces, including the evaluation of their viability. Adhesion can be studied under flow or static and at different contact times. Study of biolayers formed on materials after different growth times. Evaluation of bactericidal and/or bacteriostatic responses using viability kits or plate growth.


Applications:

Testing of materials with anti-infective objectives. Testing of compounds with antibacterial purpose.

Read More

U16-S06. Topographic characterization service using optical profilometry OUTSTANDING

This service makes it possible to determine the surface tension of both solids and liquids under controlled temperature and humidity conditions, even locally by means of deposited drops with a volume of around 10-12 L. The service will be provided by specialists in the characterization of materials in dimensions macroscopic or in colloidal systems. The service can meet the needs of business R&D&i, providing support for their controls according to ISO, ASTM, ASME and EUR standards. In addition, it can also serve research groups with detailed reports according to the needs of the study.

Read More

U16-S05. Characterization service by contact angle goniometry OUTSTANDING

This service makes it possible to determine the surface tension of both solids and liquids under controlled temperature and humidity conditions, even locally by means of deposited drops with a volume of around 10-12 L. The service will be provided by specialists in the characterization of materials in dimensions macroscopic or in colloidal systems. The service can meet the needs of business R&D&i, providing support for their controls according to ISO, ASTM, ASME and EUR standards. In addition, it can also serve research groups with detailed reports according to the needs of the study.

Read More

U13-S09. COMPRESSION-SHEAR TEST CELLSCALE MicroTester G2 (On-site) OUTSTANDING

U13-S09. COMPRESSION-SHEAR TEST CELLSCALE MicroTester G2 (On-site) OUTSTANDING

Uniaxial tensile and shear tests

Description: By detecting small changes in a force sensing micro-wire, the system can measure forces and displacements that are much smaller than a conventional mechanical test system. The system incorporates a temperature-controlled fluid bath for maintaining ideal specimen conditions and a high-quality optical system to provide user feedback

Aplications: Tension and compression and shear test of hydrogel microspheres, cell spheroids, and engineered microtissues

Read More

U8-S05 Deposition of thin films (Polyimide, Parylene) for the fabrication of flexible devices or encapsulation purposes (On-site&Remote) OUTSTANDING.

Read More

U8-S06. Encapsulation or fabrication of 3D strcutures via 3D printing.

Read More

U20-S015. Cytotoxicity: proliferation, LDH, apoptosis and ROS

Read More

U20-S014. Hemocompatibility: hemolysis, platelet aggregation, plasma coagulation times and complement activation

Read More

U20-S013. Detection of microbial (bacterial and mycoplasma) contaminationpre

Read More

U29-S02. Modification of oligonucleotides. (Remote) OUTSTANDING

Modification of oligonucleotides during and post synthesis to meet user requirements:

  • Conjugation of oligonucleotides with fluorophores (fluoresceine, Cy3, Ct5, etc..) and other types of small molecules such as biotine, lipids.
  • Conjugation to peptides.
  • Phosphorothioate linkages
  • Modified backbones such as locked nucleic acids (LNA), 2’-O-alkyl-RNA, etc..
  • Modified nucleobases: 2-aminopurine, 5-methyl-dC, etc…
  • 5’, 3’-modifications such as 5’-, 3’-amino, 5’-, 3’-thiol, etc..

Read More